Customization: | Available |
---|---|
Clapboard: | with Clapboard |
Medium Material: | Fiberglass |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Application
It is suitable for the final stage of filtration in various ventilation equipment, dust removal equipment, and air supply systems with
high requirements for cleanliness.
Features
Large filtration area and large dust holding capacity
High filtration efficiency and low resistance.
Uniform pleat space
Stable air flow.
Excellent air tightness.
Temperature resistance ≤ 80°C.
Humidity resistance (relative humidity) ≤ 100% RH (separated by aluminum foil)
Deep Pleat HEPA Filter - Box Type 150D | ||||||||
Model | Size (mm) |
CMH | I.N.P (Pa) |
F.N.P (Pa) |
Filter object (μm) |
EFF. (%) |
Filtration Class |
Filtration Area (m2) |
DP2803-10 | 305*610*150 | 500/700 | <100/130 | <350/500 | 0.3 | 85≤E<95 | E10 | 4.25 |
DP8803-10 | 610*610*150 | 1000/1500 | <100/130 | <350/500 | 0.3 | 85≤E<95 | E10 | 7.97 |
DPB803-10 | 1220*610*150 | 2000/2800 | <100/130 | <350/500 | 0.3 | 85≤E<95 | E10 | 15.68 |
DPB003-10 | 1220*915*150 | 2800/3800 | <100/130 | <350/500 | 0.3 | 85≤E<95 | E10 | 23.60 |
DP2803-11 | 305*610*150 | 500/700 | <120/150 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 4.25 |
DP8803-11 | 610*610*150 | 1000/1500 | <120/150 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 7.97 |
DPB803-11 | 1220*610*150 | 2000/2800 | <120/150 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 15.68 |
DPB003-11 | 1220*915*150 | 2800/3800 | <120/150 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 23.60 |
DP2803-12 | 305*610*150 | 500/700 | <140/170 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 4.25 |
DP8803-12 | 610*610*150 | 1000/1500 | <140/170 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 7.97 |
DPB803-12 | 1220*610*150 | 2000/2800 | <140/170 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 15.68 |
DPB003-12 | 1220*915*150 | 2800/3800 | <140/170 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 23.60 |
DP2803-13 | 305*610*150 | 500/700 | <170/200 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 4.25 |
DP8803-13 | 610*610*150 | 1000/1500 | <170/200 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 7.97 |
DPB803-13 | 1220*610*150 | 2000/2800 | <170/200 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 15.68 |
DPB003-13 | 1220*915*150 | 2800/3800 | <170/200 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 23.60 |
DP2803-14 | 305*610*150 | 500/700 | <190/220 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 4.25 |
DP8803-14 | 610*610*150 | 1000/1500 | <190/220 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 7.97 |
DPB803-14 | 1220*610*150 | 2000/2800 | <190/220 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 15.68 |
DPB003-14 | 1220*915*150 | 2800/3800 | <190/220 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 23.60 |
Deep Pleat HEPA Filter - Box Type 220D | ||||||||
Model | Size (mm) |
CMH | I.N.P (Pa) |
F.N.P (Pa) |
Filter object (μm) |
EFF. (%) |
Filtration Class |
Filtration Area (m2) |
RT-DP4404-10 | 484*484*220 | 1000/1600 | <110/150 | <350/500 | 0.3 | 85≤E<95 | E10 | 8.20 |
RT-DP2804-10 | 305*610*220 | 800/1000 | <110/150 | <350/500 | 0.3 | 85≤E<95 | E10 | 6.76 |
RT-DP8804-10 | 610*610*220 | 1500/2100 | <110/150 | <350/500 | 0.3 | 85≤E<95 | E10 | 12.68 |
RT-DPB804-10 | 1220*610*220 | 2800/4000 | <110/150 | <350/500 | 0.3 | 85≤E<95 | E10 | 24.95 |
RT-DPB004-10 | 1220*915*220 | 3800/5400 | <110/150 | <350/500 | 0.3 | 85≤E<95 | E10 | 37.54 |
RT-DP4404-11 | 484*484*220 | 1000/1600 | <140/175 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 8.20 |
RT-DP2804-11 | 305*610*220 | 800/1000 | <140/175 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 6.76 |
RT-DP8804-11 | 610*610*220 | 1500/2100 | <140/175 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 12.68 |
RT-DPB804-11 | 1220*610*220 | 2800/4000 | <140/175 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 24.95 |
RT-DPB004-11 | 1220*915*220 | 3800/5400 | <140/175 | <350/500 | 0.3 | 95≤E<99.5 | E11 | 37.54 |
RT-DP4404-12 | 484*484*220 | 1000/1600 | <160/190 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 8.20 |
RT-DP2804-12 | 305*610*220 | 800/1000 | <160/190 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 6.76 |
RT-DP8804-12 | 610*610*220 | 1500/2100 | <160/190 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 12.68 |
RT-DPB804-12 | 1220*610*220 | 2800/4000 | <160/190 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 24.95 |
RT-DPB004-12 | 1220*915*220 | 3800/5400 | <160/190 | <350/500 | 0.3 | 99.5≤E<99.95 | E12 | 37.54 |
RT-DP4404-13 | 484*484*220 | 1000/1600 | <180/220 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 8.20 |
RT-DP2804-13 | 305*610*220 | 800/1000 | <180/220 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 6.76 |
RT-DP8804-13 | 610*610*220 | 1500/2100 | <180/220 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 12.68 |
RT-DPB804-13 | 1220*610*220 | 2800/4000 | <180/220 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 24.95 |
RT-DPB004-13 | 1220*915*220 | 3800/5400 | <180/220 | <350/500 | 0.3 | 99.95≤E<99.995 | H13 | 37.54 |
RT-DP4404-14 | 484*484*220 | 1000/1600 | <200/240 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 8.20 |
RT-DP2804-14 | 305*610*220 | 800/1000 | <200/240 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 6.76 |
RT-DP8804-14 | 610*610*220 | 1500/2100 | <200/240 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 12.68 |
RT-DPB804-14 | 1220*610*220 | 2800/4000 | <200/240 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 24.95 |
RT-DPB004-14 | 1220*915*220 | 3800/5400 | <200/240 | <350/500 | 0.3 | 99.995≤E<99.9995 | H14 | 37.54 |
Mini Pleat HEPA Filter - Box Type 69D | ||||||||
Model | Size (mm) |
CMH | I.N.P (Pa) |
F.N.P (Pa) |
Filter object (μm) |
EFF. (%) |
Filtration Class |
Filtration Area (m2) |
MP2869-10 | 305*610*69 | 500/1000 | <30/70 | <300/500 | 0.3 | 85≤E<95 | E10 | 5.94 |
MP8869-10 | 610*610*69 | 900/1800 | <30/70 | <300/500 | 0.3 | 85≤E<95 | E10 | 11.48 |
MPB869-10 | 1220*610*69 | 1700/3400 | <30/70 | <300/500 | 0.3 | 85≤E<95 | E10 | 22.51 |
MP2869-11 | 305*610*69 | 500/1000 | <55/120 | <300/500 | 0.3 | 95≤E<99.5 | E11 | 5.94 |
MP8869-11 | 610*610*69 | 900/1800 | <55/120 | <300/500 | 0.3 | 95≤E<99.5 | E11 | 11.48 |
MPB869-11 | 1220*610*69 | 1700/3400 | <55/120 | <300/500 | 0.3 | 95≤E<99.5 | E11 | 22.51 |
MP2869-12 | 305*610*69 | 500/1000 | <75/180 | <300/500 | 0.3 | 99.5≤E<99.95 | E12 | 5.94 |
MP8869-12 | 610*610*69 | 900/1800 | <75/180 | <300/500 | 0.3 | 99.5≤E<99.95 | E12 | 11.48 |
MPB869-12 | 1220*610*69 | 1700/3400 | <75/180 | <300/500 | 0.3 | 99.5≤E<99.95 | E12 | 22.51 |
MP2869-13 | 305*610*69 | 500/1000 | <100/205 | <300/500 | 0.3 | 99.95≤E<99.995 | H13 | 5.94 |
MP8869-13 | 610*610*69 | 900/1800 | <100/205 | <300/500 | 0.3 | 99.95≤E<99.995 | H13 | 11.48 |
MPB869-13 | 1220*610*69 | 1700/3400 | <100/205 | <300/500 | 0.3 | 99.95≤E<99.995 | H13 | 22.51 |
MP2869-14 | 305*610*69 | 500/1000 | <110/220 | <300/500 | 0.3 | 99.995≤E<99.9995 | H14 | 5.94 |
MP8869-14 | 610*610*69 | 900/1800 | <110/220 | <300/500 | 0.3 | 99.995≤E<99.9995 | H14 | 11.48 |
MPB869-14 | 1220*610*69 | 1700/3400 | <110/220 | <300/500 | 0.3 | 99.995≤E<99.9995 | H14 | 22.51 |
MP2869-15 | 305*610*69 | 500/1000 | <160/295 | <300/500 | 0.12 | 99.9995≤E<99.9997 | U15 | 5.94 |
MP8869-15 | 610*610*69 | 900/1800 | <160/295 | <300/500 | 0.12 | 99.9995≤E<99.9997 | U15 | 11.48 |
MPB869-15 | 1220*610*69 | 1700/3400 | <160/295 | <300/500 | 0.12 | 99.9995≤E<99.9997 | U15 | 22.51 |
MP2869-16 | 305*610*69 | 500/1000 | <175/320 | <300/500 | 0.12 | 99.9997≤E<99.99997 | U16 | 5.94 |
MP8869-16 | 610*610*69 | 900/1800 | <175/320 | <300/500 | 0.12 | 99.9997≤E<99.99997 | U16 | 11.48 |
MPB869-16 | 1220*610*69 | 1700/3400 | <175/320 | <300/500 | 0.12 | 99.9997≤E<99.99997 | U16 | 22.51 |
Mini Pleat HEPA Filter - Box Type 80D | ||||||||
Model | Size (mm) |
CMH | I.N.P (Pa) |
F.N.P (Pa) |
Filter object (μm) |
EFF. (%) |
Filtration Class |
Filtration Area (m2) |
MP2880-10 | 305*610*80 | 600/1200 | <30/70 | <300/500 | 0.3 | 85≤E<95 | E10 | 7.15 |
MP8880-10 | 610*610*80 | 1100/1200 | <30/70 | <300/500 | 0.3 | 85≤E<95 | E10 | 13.82 |
MPB880-10 | 1220*610*80 | 2000/2200 | <30/70 | <300/500 | 0.3 | 85≤E<95 | E10 | 27.09 |
MP2880-11 | 305*610*80 | 600/1200 | <55/120 | <300/500 | 0.3 | 95≤E<99.5 | E11 | 7.15 |
MP8880-11 | 610*610*80 | 1100/1200 | <55/120 | <300/500 | 0.3 | 95≤E<99.5 | E11 | 13.82 |
MPB880-11 | 1220*610*80 | 2000/2200 | <55/120 | <300/500 | 0.3 | 95≤E<99.5 | E11 | 27.09 |
MP2880-12 | 305*610*80 | 600/1200 | <75/180 | <300/500 | 0.3 | 99.5≤E<99.95 | E12 | 7.15 |
MP8880-12 | 610*610*80 | 1100/1200 | <75/180 | <300/500 | 0.3 | 99.5≤E<99.95 | E12 | 13.82 |
MPB880-12 | 1220*610*80 | 2000/2200 | <75/180 | <300/500 | 0.3 | 99.5≤E<99.95 | E12 | 27.09 |
MP2880-13 | 305*610*80 | 600/1200 | <100/205 | <300/500 | 0.3 | 99.95≤E<99.995 | H13 | 7.15 |
MP8880-13 | 610*610*80 | 1100/1200 | <100/205 | <300/500 | 0.3 | 99.95≤E<99.995 | H13 | 13.82 |
MPB880-13 | 1220*610*80 | 2000/2200 | <100/205 | <300/500 | 0.3 | 99.95≤E<99.995 | H13 | 27.09 |
MP2880-14 | 305*610*80 | 600/1200 | <110/220 | <300/500 | 0.3 | 99.995≤E<99.9995 | H14 | 7.15 |
MP8880-14 | 610*610*80 | 1100/1200 | <110/220 | <300/500 | 0.3 | 99.995≤E<99.9995 | H14 | 13.82 |
MPB880-14 | 1220*610*80 | 2000/2200 | <110/220 | <300/500 | 0.3 | 99.995≤E<99.9995 | H14 | 27.09 |
MP2880-15 | 305*610*80 | 600/1200 | <160/295 | <300/500 | 0.12 | 99.9995≤E<99.9997 | U15 | 7.15 |
MP8880-15 | 610*610*80 | 1100/1200 | <160/295 | <300/500 | 0.12 | 99.9995≤E<99.9997 | U15 | 13.82 |
MPB880-15 | 1220*610*80 | 2000/2200 | <160/295 | <300/500 | 0.12 | 99.9995≤E<99.9997 | U15 | 27.09 |
MP2880-16 | 305*610*80 | 600/1200 | <175/320 | <300/500 | 0.12 | 99.9997≤E<99.99997 | U16 | 7.15 |
MP8880-16 | 610*610*80 | 1100/1200 | <175/320 | <300/500 | 0.12 | 99.9997≤E<99.99997 | U16 | 13.82 |
MP2880-10 | 1220*610*80 | 2000/2200 | <175/320 | <300/500 | 0.12 | 99.9997≤E<99.99997 | U16 | 27.09 |
Note: Other specifications can be customized according to requirements.
Q1: Are you the factory?
We have many cooperating factories here, with competitive price.
Q2:Can you send Free Sample?
Yes.We can offer you Free Samples and you just need to pay express charge. You also can provide your Express Account or asking your courier to pick up from our factory.
Q3:What's your MOQ ?
A:Different standard of MOQ for different goods.
Q4:Can the dimension be customized?
Yes, the dimension can be customized.
Q5. What is the payment terms.
The payment terms is 30%-50% as deposit, balance be paid before shipment.
Q6. What payments can be accepted?
T/T
Q7. What are your minimum order?or Can we have one sample order or small order to try?
Normally, 500sets/item,less quantity is available but cost is higher if you can accept. We warmly welcome any trial order.
Q8. Can we have our logo to be printed on the units or packaging?
Yes!OEM print is available.
Q9. How many days can I get the product if we placed purchase order?/What is the lead time?
In general,3-7 working days for Sample and Ready Stock;30-40 days for production order after receiving order deposit.
Q10. Do you offer discounts for bulk orders?
Yes, There have breakdown price for breakdown quantity, email us to speak to a representative.
Q11. Could you arrange the shipment?
Sure, we have the shipping agents, we could arrange the shipping by SEA, by AIR, as customer requests.